Alpha-Stim 100
The Alpha-Stim 100 is
packaged complete with one set of 4 self-adhesive AS-Trode™
brand silver electrodes (good for approximately 2 weeks
to 1 month of use), electrode wires, 2 probes, ear clip
electrodes, 200 felt electrodes for use with the probes
and ear clips, a 15 ml bottle of Alpha Conducting
Solution™ (ACS), a 9 volt battery, carrying case, and
illustrated Owner’s Manual.
This is everything necessary to begin to use the Alpha-Stim
100 right away. Replace self-adhesive and felt
electrodes only with authorized Alpha-Stim and AS-Trode™
brand products.

Five Year Warranty: Each
Alpha-Stim 100 is warranted to be free from defects in
materials and workmanship under normal use for a period
of five years except for replacement of batteries and
accessories. See Owner’s
Manual for complete details.
Technical Specifications:
| Electrical |
|
|
|
|
Power
Source |
One 9
volt battery (included). Replace with disposable
batteries (alkaline preferred). |
|
Timer
Settings |
Probe
(10 seconds on, alternating with 2 seconds off),
10, 20, 60 minutes, and continuous. |
|
Current |
10 to
600 µA continuously adjustable. |
|
Frequency |
0.5,
1.5, or 100 Hz (pulses per second). |
|
Waveform |
Bipolar asymmetric rectangular waves, 50% duty
cycle, 0 net current (see graphic depiction
above). |
| |
|
|
|
| Mechanical |
|
Carrying Case |
|
|
Height |
13.5
cm |
Height |
20.8
cm |
|
Width |
6.4
cm |
Width |
26.9
cm |
|
Depth |
3.3cm including
belt clip |
Depth |
4.6 cm |
|
Weight |
156gm
with battery |
Shipping Weight With Unit |
0.91 kg |
Prescribing Information
CE
conformity statement for Europe:
The Alpha-Stim
100 is a class IIa, Type B
medical device. It has been independently tested by
outside agencies in order to provide assurance of
conformity to applicable standards for medical equipment
safety and electromagnetic compliance.
Caution statement for
United
States:
Federal Law
(USA only) restricts this device to sale by, or on the
order of a licensed health care practitioner. Outside of
the USA it is available world wide without a
prescription but consultation with a qualified health
care professional is recommended for difficult and
unresponsive problems or when used in conjunction with
pharmaceuticals or other therapeutic intervention.
Indications: Alpha-Stim 100 cranial
electrotherapy stimulation (CES) technology is
continuously being subjected to rigorous study and
evaluation by the international medical community.
Findings to date indicate that the Alpha-Stim 100 is an
effective treatment with broad applications for a
variety of syndromes involving pain, and for the
management of anxiety, depression, and/or insomnia, or
for the short term relief of the symptoms of pain,
anxiety, depression and/or insomnia. In many cases it is
the sole therapeutic method required. Effective results
in pain management have been seen during and/or
subsequent to stimulation over affected body parts,
adjacent areas, and areas distant from those in pain. As
with any therapeutic intervention, not all people will
respond to the Alpha-Stim 100. The degree of efficacy
will vary with the nature of the problem being treated,
the overall health of the person, and with the method of
treatment.
Contraindications: The Alpha-Stim 100 may effect
the operation of cardiac pacemakers (particularly demand
type pacemakers). Do not stimulate directly on the eyes,
or over the carotid sinus (on the neck beside the
larynx).
Precautions: For external use only. Do not allow
children to use or handle this device without adult
supervision. Do not operate potentially dangerous
machinery or vehicles during, and in some cases, for
several hours after treatment. Caution is advised in
cases where other forms of analgesia (pain control)
would not be used; such as to retain the beneficial
aspects of pain for diagnosis or in cases where people
may overuse pain-controlled areas. Safety of stimulation
has not been established during pregnancy. There have
been isolated reports of blood pressure being lowered by
CES so care should be taken while using the Alpha-Stim
100 with high blood pressure medication.
Adverse Effects: Adverse effects are usually mild
and self-limiting. Adverse effects seen in approximately
4,541 patients in controlled, open, uncontrolled
conditions, and by physician survey and reasonably
associated with the use of CES are dizziness (6 cases,
0.13%), skin irritation/electrode burns (5 cases,
0.11%), and headaches (9 cases, 0.20%). Prolonged CES
treatment at higher than necessary currents may cause
dizziness or nausea that can last from hours to days.
Treatment immediately prior to going to sleep may cause
difficulty sleeping due to increased alertness. It is
recommended that CES be used at least 3 hours before
going to sleep. Paradoxical reactions such as
hyperexcited states,
increased anxiety, and sleep disturbances may occur.
Price: $795.00
-

1) Licensed Healthcare
Practitioner Directions:
When confirming your order please enter the type of
license you hold and your license number in the comment
section of the check out page of our shopping cart.
2) Ordering By Prescription Directions:
If you are not a healthcare practitioner you
will need to fax the prescription you have obtained
from a healthcare practitioner to us at
410-956-0306. When
confirming your order please put the name of the healthcare
practitioner providing the prescription in the COMMENT
box. You DO NOT need to fill in license type
and number on the order form. Once we receive the prescription,
we will process your order.
|
|
Award
Winning - "The Different Shades
of Autism". Now available in English, Spanish
& Portuguese. Click here
for more details and how to order on-line! |
| Frequently Asked Questions About Autism
|
|
Use this free translator Translate content on this
page to another language.
|
|